Surface Area and Pore Size Distribution Analyzer By Beijing JWGB Sci & Tech. Co., Ltd.,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Surface Area and Pore Size Distribution Analyzer
Next

Surface Area and Pore Size Distribution Analyzer

( Negotiable )

|

1 Set Minimum Order

Pays:

China

N ° de modèle:

JW-BK200B

Prix FOB:

( Negotiable ) Obtenir le dernier prix

Localité:

Beijng, China

Prix de commande minimale:

-

Commande minimale:

1 Set

Packaging Detail:

-

Heure de livraison:

30 days

Capacité de Fournir:

1000 Set per Year

Payment Type:

Other, PayPal, D/P, L/C, T/T

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Ms. Wendy

A Block,No.23,South Binhe Road, Beijing, Beijing

Contacter maintenant

Spécification du produit

  • Brand Name: JW-BK200B

La description

Test principle: the static volumetric method, gas adsorption;
Analysis Models: BET, Langmuir, BJH, t-plot, DR, αs-plot, MP, HK, SF, and NLDFT;
Measuring range: surface area ≥ 0.**5M2/g, no upper limit; mesoporous and macroporous 2 _ **0nm; micropore size 0.*5nm _ 2nm; pore volume 0.***1 cm3/g, no upper limit.
Sorption gas:N2 (high purity); Ar, Kr, CO2, CH4, etc. available
Analysis Stations: 2 ports. One analysis station can test the micropore and the other can test the mesorpore.
Sample Type: powders, granules, fibers, flakes and other materials
Pressure Sensor: ***0torr (**3kpa), *0torr (1.*3kpa); 1torr (0.**3kpa) or 0.1torr (0.***3kpa); accuracy≤± 0.*5%(P.S)
P0 tube: there is a separate P0 tube in every analysis port, two in all, controlled by a separate pressure sensor, completely separates from the analysis port, real-time detecting the nitrogen saturation vapor pressure, and participating in the theoretical calculation; also the atmospheric method to determinate the P0 accurately;
Cold trap tube: sample degassing system has a special cold trap device that can effectively remove the water, hazardous substances and other impurities, degassed from the special sample, and it can avoid the contamination of the vacuum system;
Degassing system: Parity, ectopic vacuum degassing pretreatment systems are controlled by separate pressure sensors. Two samples can be analyzed simultaneously, also two samples can be degassed in degassing ports; two independent sample degassing stations are separate from the sample analysis ports. The degassing system has two independent heating packages, two independent temperature control systems, which can be programmed by temperature control; you can choose another four external vacuum degassing pretreatment system;
Degassing temperature: room temperature ***0℃, accuracy ± 1℃;
Nitrogen Partial Pressure: P/Po 1×***8 _ 0.**8, the minimum resolvable relative pressure 5 × ***7
Ultimate vacuum:≤ *0P*6 Pa(7.5×***9 torr), mechanical pump and turbo molecular pump.
Pressure Accuracy: ≤ ± 0.*5% (P.S)
 

Pays: China
N ° de modèle: JW-BK200B
Prix FOB: ( Negotiable ) Obtenir le dernier prix
Localité: Beijng, China
Prix de commande minimale: -
Commande minimale: 1 Set
Packaging Detail: -
Heure de livraison: 30 days
Capacité de Fournir: 1000 Set per Year
Payment Type: Other, PayPal, D/P, L/C, T/T
Groupe de produits : Static Volumetric Method

Send a direct inquiry to this supplier

To:

Ms. Wendy < Beijing JWGB Sci & Tech. Co., Ltd. >

Je veux savoir: