AC Hipot test | |||
Booster rated output capacity | **0VA(***0V/**0mA) | ||
Booster maximum short-circuit current | >**0mA | ||
Output waveform | Sine wave, <3%(pure resistance,***0V/1mA),<3%(From empty load to full load) | ||
Output voltage setting | Range | **0~***0V | |
Resolution | 5V | ||
Accuracy | ±ï¼ˆ3%×setting**0V) | ||
Frequency setting | Range | *0Hz/*0Hz | |
Accuracy | ±0.1%×setting | ||
Alarming limits setting | Current upper-limit | 0.*0~*9.*9mA | |
Current lower-limit | 0.*0~*0.*0mA | ||
Compensation current setting | Range | 0.*0~*0.*0mA, automatic testing, compensation can be set to ON/OFF | |
Time setting | Range | 1~**9s | |
Ramp up time range | 1~**0s | ||
Accuracy | ±ï¼ˆ0.1%×setting*1count) | ||
Breakdown current alarm | Range | 0.*0~*9.*9mA | |
Accuracy | ±ï¼ˆ3%×reading*3counts) | ||
Insulation Resistance test | |||
Rated output capacity | 2VA(***0V/2mA) | ||
Output voltage regulation | <3%(From no load to full load) | ||
Output voltage ripple | <1% | ||
Output voltage setting | Range | DC **0Vor***0V | |
Accuracy | ±ï¼ˆ3%×setting*3counts) | ||
Alarming limits setting | Resistance upper-limit range | 0.0~*9.9 MΩ,**0~***0MΩ(If upper-limit is set to 0, it will not make adjudgment for upper limit) | |
Resistance lower-limit range | 0.3~*9.9 MΩ, **0~***0MΩ | ||
Time setting | Range | 1~**9s | |
Accuracy | ±ï¼ˆ0.1%×setting*1count) | ||
Insulation resistance measurement | Range | 0.0~*9.9 MΩ, **0~***0 MΩ | |
Accuracy | ≤**0MΩ: ±ï¼ˆ3%×reading*3counts) | ||
>**0MΩ:±ï¼ˆ8%×reading*8counts) | |||
Ground Bond Resistance test | |||
No load output voltage | <*2V | ||
Output current setting | Range | 3~*0A | |
Accuracy | ±ï¼ˆ3%×setting*0.2A) | ||
Current range instruction | Optional: 3 ~ *4A test current | ||
Current frequency setting | Range | Sine waveform *0Hz/*0Hz | |
Accuracy | ±0.1%×setting | ||
Test time setting | Range | 1~**9s | |
Accuracy | ±ï¼ˆ0.1%×setting*1count) | ||
Result display mode | Ground resistance or voltage | ||
Ground resistance display mode | |||
Alarming limits setting | Resistance upper-limit range | 3A≤output current≤*0A:*0~**0 mΩ | |
Resistance lower-limit range | 0~**0 mΩ | ||
Compensation resistance setting | Range | 0~**0 mΩ, automatic testing, compensation can be set to ON/OFF | |
Ground bond resistance measurement | Range | *0~**0 mΩ | |
Accuracy | ±ï¼ˆ3%×reading+ 5counts) | ||
Ground voltage display mode | |||
Alarming limits setting | Voltage upper-limit range | *0~***0 mV | |
Voltage lower-limit range | 0~***0 mV | ||
Compensation voltage setting | Range | 0~***0 mV, automatic testing, compensation can be set to ON/OFF | |
Ground bond resistance measurement | Range | *0~***0 mV | |
Accuracy | ±ï¼ˆ3%×reading+ *0mV) | ||
Leakage Current test | |||
Leakage current test type setting | Single phase load, static/dynamic leakage current | ||
MD network selection | Standard IEC ******1 figure 4 networkï¼›other test network optional | ||
Alarming limits Setting | Current upper-limit range | 0.**0~9.**9mA | |
Current lower-limit range | 0.**0~5.**0mA | ||
Leakage current compensation setting | Range | 0.**0~1.**0mA, automatic testing, compensation can be set to ON/OFF | |
Time test setting | Range | 1~**9s | |
Accuracy | ±ï¼ˆ0.1%×setting*1count) | ||
Leakage current measurement | Range | 0.**0~9.**9mA | |
accuracy | DC~*0kHz:±ï¼ˆ3%×reading*0.**0mA) | ||
Output voltage measurement | Range | *0~**0V(phase voltage) | |
accuracy | ±ï¼ˆ0.5%×reading*2counts) | ||
Run Power Only forAN***1S(F)/AN***1F(F)/AN***1B(F) | |||
Alarming limits setting | Power upper-limit range | 6~***0W | |
Power lower-limit range | 0~***0W | ||
Test time setting | Range | 1~**9s | |
Accuracy | ±ï¼ˆ0.1%×setting*1count) | ||
Voltage measurement | Range | *0~**0V(phase voltage) | |
Pays: | China |
N ° de modèle: | - |
Prix FOB: | 1 ~ 20000 / Unit ( Negotiable ) Obtenir le dernier prix |
Localité: | Qingdao,China |
Prix de commande minimale: | 1 per Unit |
Commande minimale: | 1 Unit |
Packaging Detail: | wooden case |
Heure de livraison: | - |
Capacité de Fournir: | 200 Unit per Month |
Payment Type: | T/T, L/C, D/A, D/P, PayPal |
Groupe de produits : | - |