1 Product uses
Decoupler is a AC Interference protection product, which sets Embedded-type line flowing and surge protector in one.
It is mainly used in long-distance buried pipeline engineering. As following situations: high-tension transmission line tower and communication tower and their ground system which near the pipeline; public passage between high-tension transmission line and pipeline; cross of pipeline and transmission line or Electrified railway-parallel pipe; the installation of the decoupler can reduce the influence of DC, AC & stray current or thunder flow on the buried pipelines, also strengthen stability of pipeline cathodic protection potential.
2 Codes and Standards
—GB/T***3.1 Environmental testing - Part 2: Test methods -Tests A: Cold.
—GB/T***3.2 Environmental testing - Part 2: Test methods -Tests B: Dry heat.
一GB/T***3.3 Environmental testing for electric and electronic products - Part 2: Testing method - test Cab: Damp heat Steady state.
—GB/T***3.5 Environmental testing for electric and electronic products Part 2:Test methods Test Ea and guidance: Shock.
一GB/T***3.*0 Environmental testing for electric and electronic products - Part 2: Test methods Test FC and guidance: Vibration (Sinusoidal).
一GB****2 Metal-oxide surge arresters without gaps for a.c. Systems;
—GB***8 Degrees of protection provided by enclosure(IP code);
—GB ****2.1/1 EC ******1 Surge protective devices connected to low-voltage power distribution systems*-Part 1: Performance requirements and testing methods
一SY/T ***2 Standard for AC influence drainage protec tion of buried steel pipeline.
3 Main technological performance
3.1 Environmental parameter Operating environment: **5'tD~**5cC Relative humidity: *0%〜*0%RH
{C}3.2 {C}The insulation resistance between the terminals and the box should be not lessthan *0MQ.
{C}3.3 {C}The maximum lightning shock(8/*0 m s) current that the decoupler can be tolerated should be not less than **0KA.
{C}3.4 {C}The maximum fault current that the decoupler can be tolerated should be no less than ***0A.
{C}3.5 {C}The scope of the isolation voltage is-UN 〜+UN,Allow the error is not more than 0.2UN. ( UN can be set according to the requirement of user.)
{C}3.6 {C}In the rated isolation voltage, the DC current leak shall be not more than 1mA.
{C}3.7 {C}In the rated Isolation Voltage, The AC(*0HZ) steady-state current should be not less than *5A.
{C}3.8 {C}DC steady-state current should be not less than 5A.
{C}3.9 {C}IP protection grade reaches IP*5.
Â
Pays: | China |
N ° de modèle: | QOH-1 |
Prix FOB: | Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | - |
Packaging Detail: | Wooden Case |
Heure de livraison: | 15-20 days |
Capacité de Fournir: | 200 Set per Month |
Payment Type: | - |
Groupe de produits : | - |