SLAC-H By Qingdao Universe Power New Energy Technology Co., Ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
SLAC-H
Next

SLAC-H

20 ~ 39 USD /

|

1 Unit Minimum Order

Pays:

China

N ° de modèle:

-

Prix FOB:

20 ~ 39 USD / Obtenir le dernier prix

Localité:

-

Prix de commande minimale:

20

Commande minimale:

1 Unit

Packaging Detail:

-

Heure de livraison:

-

Capacité de Fournir:

5000 Unit per Month

Payment Type:

PayPal, T/T

Groupe de produits :

-

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Jay

No 110 Huangdao districtQingdao Shandong, Qingdao, Shandong

Contacter maintenant

Spécification du produit

  • Brand Name: UPNE-TECH
  • Rated Voltage: 12V/24V
  • Maximum Current: 50A

La description


Our product has a number of safety and display functions.
Clear readable LED display of the state of charge.
Acoustic signal when the state of charge changes.
Low voltage disconnect regulated by state of charge or voltage.
The controller adjusts itself automatically to *2V or *4V system voltage.
Max.*6 mm² connector binding posts. Max safety current can reach *1A.
The charging characteristics include automatic adoption to the ambient temperature.
Complete electronic protection.
Wiring and grounding:
The controller is intended for indoor use only or installed in distribution box. Protect it from direct sunlight and rain. If installed in distribution box, should avoid the position of condensed water drip. The controller measures the ambient temperature to adapt the charging voltage. To ensure the start-up of controller, battery voltage should exceed *0V if the system voltage is *2V, and battery voltage should exceed *0V if the system voltage is *4V.
If the battery voltage is not within the normal operation range at start-up, a status display according to the section ERROR DESCRIPTION occurs.
Connect the controller by following steps to avoid installation faults.
1. Connect the wire to the controller, then to the battery.
2. Connect the wire to the controller, then to the photovoltaic modules.
3. Connect the wire to the load, then to the controller.
                                    
 All positive connections of SLAC-H controller are common and therefore have the same electrical potential. If any grounding is required, always do this on the positive wire. Special grounding terminal can be used for controller shell grounding.
If the controller is used in a vehicle which has the battery negative on the chassis, loads connected to the controller must not have an electric connection to the car body. Otherwise the Low Voltage Disconnect function and the electronic fuse function of the controller are short circuited.
REMARK:Mind the recommendations of your battery manufacturer. We strongly recommend connect a fuse directly to the battery to protect any short circuit at the battery wiring. The fuse must correspond to 1.5 times the nominal current of the controller.
Starting up the controller:
Self Test
As soon as the controller is supplied with power from the battery, it starts a self test routine. Then the display changes to normal operation.
The controller adjusts itself automatically to *2V or *4V system. As soon as the voltage at the time of start-up exceeds *0V, the controller assumes a *4V system.
If the battery voltage is not within the normal operation range at start-up, a
status display according to the section ERROR DESCRIPTION occurs.

Safety features:
SLACH safety features can protect the controller to avoid damage to products due to incorrect installation or use.
  PV terminals Battery terminals Load terminals
Reverse polarity Protected(Not at *4V system voltage.) Protected (buzzer alarm warning) Protected (1)
Short circuit Protected (2) Protected(3) (with fuse on battery) Switches off immediately(2)
Over current Controller will limit the current. Protected Switches off with
a delay (4)
Reverse charge Protected No effect No effect
Overvoltage Max. *5V Max. *5V Switches off above
*5.5V/*1.0 V
Under voltage No effect Switches off load Switches off
Over temperature  

Pays: China
N ° de modèle: -
Prix FOB: 20 ~ 39 / Obtenir le dernier prix
Localité: -
Prix de commande minimale: 20
Commande minimale: 1 Unit
Packaging Detail: -
Heure de livraison: -
Capacité de Fournir: 5000 Unit per Month
Payment Type: PayPal, T/T
Groupe de produits : -

Send a direct inquiry to this supplier

To:

Mr. Jay < Qingdao Universe Power New Energy Technology Co., Ltd >

Je veux savoir: