Single-phase medical isolation
transformer provides
power for
single-phase IT system,
with the static shielding is installed between
the primary
winding and secondary winding. This
transformer is
seamlessly rolled by high quality cold rolled silicon steel strip
and characterized by low iron loss, good thermal diffusivity of
winding, low temperature rise, good uniformity of winding, low
magnetic interference, etc. It is specially used for medical and
high standard special facilities. And there is a built-in high
precision temperature probe whose data can be uploaded in
synchronization with that of insulation monitor and other
equipments.
The characteristics of medical
isolation transformer at the end of the AC power
supply:
1. Eliminating
third harmonic and the third harmonic of more serious interfering
signals on the power grid, and reducing interfering
signals.
2. Producing
new neutral conductor and preventing the equipment from
working abnormally due to bad neutral line on the power
network.
3. Isolating
the current waveform distortion caused by non-linear load (such as
third harmonic) without polluting the power
grid.
The characteristics of medical
isolation transformer at the output end of the AC power
supply:
1. Preventing
the non-linear load current distortion from affecting the normal
working of AC power supply and polluting the power grid to improve
the quality of power network.
2. Preventing
the non-linear load current distortion from affecting the precision
of sampling at the end of the isolation transformer to gain
controlling signal which can reflect the actual
situation.
3. Without
affecting the normal working of regulated power supply in
the situation of unbalanced load.
Technical
parameters:
1. Rated power: 6.3 KVA, 8 KVA, *0
KVA
2. Primary voltage **0V, secondary voltage
**0V
3. Working frequency:
*0/*0Hz
4. No-load current <
2A
5. Full-load temperature rise <
**5K
6. Insulation class:
H.
7. Medical leakage current <
*0uA
8. Noise level <
*5db
9. Insulation
resistance: DC**0V;**0MΩ
MIN
*0. Protection grade:
IPOO
Application environment
and conditions:
1, The altitude is not more
than ***0 meters and if more than ***0 meters, derating is
required.
2, Running temperature: *5
℃ - *0 ℃, relative humidity is less than
*0%.Â
3, Without harmful gas, inflammable,
explosive and conductive dust around.
Pays: | China |
N ° de modèle: | - |
Prix FOB: | 10 ~ 15000 / Piece Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | 10 per Piece |
Commande minimale: | 1 Piece |
Packaging Detail: | packing in wooden cases |
Heure de livraison: | 2-3 weeks |
Capacité de Fournir: | 5000 Piece per Month |
Payment Type: | T/T |
Groupe de produits : | Medical isolation transformer |