SHM3012 Patient monitor By Beijing Slan International Co., Ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
SHM3012 Patient monitor
Next

SHM3012 Patient monitor

1 / Piece

|

1 Piece Minimum Order

Pays:

China

N ° de modèle:

SHM3012

Prix FOB:

1 / Piece Obtenir le dernier prix

Localité:

China

Prix de commande minimale:

1 per Piece

Commande minimale:

1 Piece

Packaging Detail:

1x1x1

Heure de livraison:

1

Capacité de Fournir:

11 Piece per Day

Payment Type:

Money Gram, Western Union, L/C, T/T

Groupe de produits :

-

Contacter maintenant
Membre gratuit

Personne à contacter shawn

Daxing, Beijing, Beijing

Contacter maintenant

Spécification du produit

La description

Power: **0~**0V AC, *0/*0 Hz
Battery:Lead-acid recharge battery
Working more than **0 minutes when full charge
About 5 minutes working after first low-power alarm
Battery charge time is not more than *2 hours

ECG

Lead mode: *-lead or *-lead
Lead selection: I, II, III, AVR, AVL, AVF, V
Gain: x **0, x **0, x ***0, x ***0
HR range: Adult: *5 ~ **0 bpm
         Pediatric/neonate: *5 ~ **0 bpm
Accuracy: ±1% or ±1bpm, which is greater
Resolution: 1 bpm
Sensitivity: >**0 uV
Input resistance: >5M Ohm
CMRR: Diagnosis mode: >*0 dB
       Monitor mode: >**0 dB
       Operation mode: >**0 dB
Electrode offset potential: ±**0mV
Pacemaker Pulse Detecting: YES
ECG signal range: ±8 mV
S-T detection: YES,
Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable

RESP

Technique: Trans-thoracic impedance (RA-LL or LA-LL)
Measurement range: Adult: 6 ~ **0 BrPM
                 Pediatric/neonate: 6 ~ **0 BrPM
Resolution: 1 BrPM
Accuracy: ±2 BrPM
Apnea alarm: *0 ~ *0 s

SpO2

Measurement range: 0 ~ **0%
Resolution: 1%
Accuracy: *0 ~ **0%: ±2%
         0 ~*9%: unspecified

Pulse Rate

Measurement range: 0 ~ **4 bpm
Resolution: 1 bpm
Accuracy: ±2 bpm

TEMP

Transducer: YSI/CYF series
Channel: dual-channel
Measurement range: 0 ~ *0℃
Resolution: 0.1℃
Accuracy: ±0.1℃

NIBP

Measurement mode: Manual/auto pulse wave oscillation
Measurement interval time: 1,2,3,4,5,*0,*5,*0,*0,*0,**0,**0,**0,**0min
Continuous measuring time: 5 min
Measurement range:
     Adult:
Systolic: *0 ~ **0 mmHg
           Diastolic: *0 ~ **5 mmHg
           Mean arterial: *0 ~ **5 mmHg
     Pediatric:
Systolic: *0 ~ **0 mmHg
           Diastolic: *0 ~ **0 mmHg
           Mean arterial: *0 ~ **5 mmHg
     Neonate:
Systolic: *0 ~ **5 mmHg
           Diastolic: *0 ~ **0 mmHg
           Mean arterial: *0 ~ **0 mmHg
Accuracy: the mean error shall be less than ±5 mmHg, the standard deviation shall be less than ±8 mmHg
Overvoltage protection: YES

Recorder(optional)

Width: *8mm
Speed: *5mm/S
Wave: 2
Type: 8s, *6s, *2s real-time record

IBP(optional)
Channel: 2 channels
Transducer sites: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ **0 mmHg
PA: *6 ~ **0 mmHg
CVP/RAP/LAP/ICP: **0 ~ *0 mmHg
P1/P2:  **0 ~ **0 mmHg
Press Sensor Sensitivity: 5 uV/V/mmHg
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which is greater
Actualization interval: about 1s

EtCO2(optional)
Measurement Mode: Side-stream or Mainstream
Measurement range: 0% ~ *3%
Resolution: 1 mmHg
Accuracy: 2 *@********************
Apnea alarm: YES

Pays: China
N ° de modèle: SHM3012
Prix FOB: 1 / Piece Obtenir le dernier prix
Localité: China
Prix de commande minimale: 1 per Piece
Commande minimale: 1 Piece
Packaging Detail: 1x1x1
Heure de livraison: 1
Capacité de Fournir: 11 Piece per Day
Payment Type: Money Gram, Western Union, L/C, T/T
Groupe de produits : -

Send a direct inquiry to this supplier

To:

shawn < Beijing Slan International Co., Ltd >

Je veux savoir: