Product introduction:
Â
Precision air conditioner refers to a special air conditioner that
can meet the operating conditions of the computer room, or can
provide a constant temperature and humidity environment for the
equipment. Under normal circumstances, in the computer room and the
environment with many precision instruments and equipment, if the
temperature and humidity are not properly controlled, it will
increase the loss of the enterprise and shorten the service life of
the equipment.
Â
Features:
Wide
Cooling Capacity Range and Various Cooling System
*****0kW.
Single circuit indoor unit,dual circuit indoor unit;
Single circuit condenser,dual circuit condenser.
Cooling system:DX(air cooled,water cooled) *0.5kW***2kW,CW(chilled
water cooled)*1.5kW***0kW, and Dual Cool (DX+CW)*6.8kW***2kW.
Â
Precise Temperature and Humidity Control
- Cyber Master has constant temperature and humidity
function,humidity function, temperature control accuracy of
±1℃,relative humidity control accuracy of ± 5%.
- Temperature control accuracy can reach ±0.5℃and relative
humidity control accuracy can reach±2% for laboratory, warehouse
and so on. Â
High
Adaptability
- Various air discharge choices including Downflow and Upflow
and so on.
- Multiple monitoring interface.
- Suitable for various ambient temperature conditions.
(Optional low temperature startup kits)
- Customized design available.
Advantage:
Precise
and reliable
Careful design, strict laboratory testing and comprehensive quality
control ensure the unit has excellent reliability;The unit uses
parts of world-renowned brands to ensure the high reliability and
service life of the whole machine. Energy saving and high
efficiency
Energy saving and high efficiency
Save a lot of energy consumption in a reasonable and feasible way,
and make full use of natural resources; The unit uses a
high-efficiency fan and a fully enclosed compressor system to
reduce operating costs and always pay attention to energy
efficiency.
Multiple air supply
The air supply method of the air-conditioned room depends on the
source and distribution characteristics of the heat in the room.
According to the dense arrangement of equipment in the computer
room, the number of cables and bridges, and the wiring method, the
air supply method of the air conditioner is divided into lower
delivery, upper return, top feed back, top feed side back, side
feed side back.
Static pressure box air supply
The air conditioner in the computer room usually does not use
pipes, but uses the space at the lower part of the raised floor or
the upper part of the ceiling as the return air of the static
pressure box. static pressure is equal.
If you are interested in my products, please click my avatar and
send an email to consult me. I have many similar related
products.