The Powtech PT**0 series inverter is a high-performance current
vector inverter based on the European power and the latest control
theoretical and technological achievements and combining with the
latest market power technology application requirements, which
introduces new high-performance current right amount inverter to
control motor perfect by servo function for a comprehensive
solution to the filed of high-end control
The Series inverter is a high-quality and multifunction vector
control inverter . It can run a wide range of speed and torque
control in high-precision by decoupling control of motor magnetic
flux current and torque current torque :fast and accurately
High-end hardware platforms , scientific production technology and
complete testing equipment make the product more stable and
reliable
Specification range
 Inverter model: PT***-XXXG-G1
Voltage level: single-phase **0V ***5%
Power range: 0.**3.7kW
Frequency range: 0.*0 ~ **0.*0Hz
Control system: high-performance vector control based on the
DSP
Way of control: V/F control, open-loop magnetic flux vector
control , PG vector control
Start torque: G type: 0.*5Hz/**0%
Input signal | |
Running method | Â Keyboard/terminal/communication |
Frequency setting |
7 kinds of frequency setting, including adjustable DC ***0v range, adjuststable DC ***0mA range, panel potentiometer, etc |
Starting signal | Forward, Reverse |
Multi-segments speed | Up to *6 segments speed can be set(using the multi-function terminal or program run) |
Multi-segments acceleration | up to 4 segments acceleration can be set(using the multi-function terminal) |
Emergency stop | Interrupt controlle output |
Pendulum-frequency running | Process control running |
Jogging | Running slowly |
Fault reset | When the protection function is active, you can automatically or manually reset the fault condition |
PID feedback signal | 包括DC 0~*0V,DC 1~5V,DC 0~*0mA,DC 4~*0mA |
Output signal | |
Running status | Motor status display, stop, acceleration and deceleration, constant speed, the program running state |
Fault output | contacting point output AC **0V 5A, DC *0V 5A |
Analogue output |
Two ways analog output, you can select the eight kinds of frequency, current, voltage, temperature and other 8 signals, the output signal range can be set arbitrarily on the range of ***0V/***0mA |
Output signal | Up to 3 output signals and there 9 signal for selection. |
Running function | |
Running function | Frequency limit, avoiding frequency ,slip compensation,reverse protection, self-tuning,PID control. |
DC current brake | Built- in PID regulate braking acurrent to ensure adequate braking torque without over current |
Operation command channels |
Three channels: the operation panel set, control terminals set, serial communication port set. Variety of means swiching |
Frequency source |
There are 6 kinds of frequency source: digital set, analog voltage set, analog current set,multi segment speed set, a serial port set,PID set, Variety of means switching |
Input terminal |
6Â digital terminals, compatible with active PNP or NPN methods two analog terminal, which AI1 can only be used as voltage, AI2 can be as voltage or current (if it needs to expand , output terminals function) |
Output termina |
A digital output terminals(dual polarity output) a relay output terminals an analog output terminals, 0/4 mA**0mA or 0/2V**0V is optional, the set frequency ,frequency output, speed and other output of the physical quantities can be achieved. |
Display | |
 Running information |
There are six operation monitoring objects: set frequency, the actual frequency, the actually motor current, current percentage, DC bus voltage, the output voltage, motor actual speed, accumulative total running time, IGBT temperature, PID set value, PID feedback values, the terminals state, output terminals state, analog AI1, analog AI2, the current number of segments, torque set value |
Error information | Up to five error message can be stored, when there is the failure ,the fault type,voltage ,caurrent, frequency and working state can be inqured |
LED display | Display parameter |
OLED display | Optional parts ,Chinese/English display operation content |
Parameter copy | Â use parameters special kepad can realize the copy of parameters quickly(only for OLED) |
Key lock and function selection | Â Keypad can be partly or fully locked. Define part of the keys effect scope to avoid faulty operation |
extranal
packing box
|
1 |
Packing list |
1 piece |
Inverter |
1 set |
Â
|
Pays: | China |
N ° de modèle: | PT200-004G-1B |
Prix FOB: | 196 ~ 278 / Unit ( Negotiable ) Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | 196 per Unit |
Commande minimale: | 1 Unit |
Packaging Detail: | 1 set per box |
Heure de livraison: | 7 days after confirm |
Capacité de Fournir: | 6000 Set per Month |
Payment Type: | Other, PayPal, Money Gram, Western Union, D/A, L/C, T/T |
Groupe de produits : | PT200 series |