MTS-100 Meter Test System By Kongter Test & Measurement Co. Ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
MTS-100 Meter Test System
Next

MTS-100 Meter Test System

|

- Minimum Order

Pays:

China

N ° de modèle:

MTS-100

Prix FOB:

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Heure de livraison:

-

Capacité de Fournir:

-

Payment Type:

-

Groupe de produits :

-

Contacter maintenant
Membre gratuit

Personne à contacter Diana

Langshan Road, Shenzhen, Guangdong

Contacter maintenant

La description


 
Phase: 3
Accuracy class: 0.*5 or 0.1
AC voltage output: ****2V
AC current output: ****0A
This Meter Test System features state-of-art designing with high accuracy. It is composed of high accurate (class 0.*5% or 0.1%) standard reference meter and power source (up to **0A). This system is particularly designed with modular structure for calibration and test of different single phase/3 phase electronic/inductive active and reactive energy meters.
 
 
Main function:

  • Calibrate all kind of single/three phase electronic/inductive active and reactive energy meter;
  • Automatically or single-step manually test basic error, creeping, starting, standard deviation of single/three phase energy meter, save user-defined calibrating scheme in Auto calibration;
  • Support variables influence tests, such as: Voltage, frequency, harmonics, reverse phase sequence, Voltage unbalance, etc.
  • Support special tests in energy meter type test, such as: phase triggering, pulse train triggering, etc. 
  • Support DLT***5 communication protocol,multi-testing of  multifunction meter such as: demand indication error, demand cycle error, time slot switching error, energy error of different tariff period, etc.
  • With OCXO, daily error of energy meter can be detected;
  • Output 2nd ~*3rd harmonics.
 
Main features:
  • 8 color touch screen, interface friendly, easy to operate;
  • Equipped with RS**2, Ethernet, and WiFi interface, MTS***0 can either support stand-alone operation, PC control or handy wireless terminal control;
  • Communicate with tested meters thru RS***5;
  • Automatically calculate the error of meter, and the related data can be downloaded thru U-disk;
  • Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;
  • Automatically detect, diagnose and alarm for failure.
  • Remotely updating online, easily achieve software updating;
  • Support calibration by user locally.
 
Order Info
MTS-**0 contains 2 models with different accuracy below:
MTS***0C: Accuracy Class 0.*5
MTS***0B: Accuracy Class  0.1
 
Technical Specification
AC Voltage output:
Range: **0V, **0V, **0V;
Adjusting range: (0~**0) %RG, RG refers to range;
Adjusting resolution: 0.*1%RG, 0.1%RG, 1%RG, or *0% RG;
Stability: 0.*1%/2min (Class 0.*5), 0.*2%/2min (Class 0.1);
Distortion: ≤0.2% (Non capacitive load);
Max output load: *0VA each phase;
Accuracy: 0.*5%RG (Class 0.*5), 0.1%RG (Class 0.1);
AC Current output:
Range: 0.*5A, 0.2A, 1A, 5A, *0A, **0A;
Adjusting range: (0~**0) %RG, RG refers to range, similarly hereafter;
Adjusting resolution: 0.*1%RG, 0.1%RG, 1%RG, or *0% RG;
Stability: 0.*1%/2min (Class 0.*5), 0.*2%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: **0VA (**0A range)
Accuracy: 0.*5%RG (Class 0.*5); 0.1%RG (Class 0.1)
Power output
Power output stability: 0.*1%/2min (Class 0.*5), 0.*2%/2min (Class 0.1)
Active/reactive power measurement accuracy: 0.*5%RG;
Phase output
Output adjusting range: 0°~**0°;
Output adjusting resolution: *0°, 1°, 0.1°, or 0.*1°;
Resolution: 0.*1°;
Measurement accuracy: 0.*5°.
Power factor output:
Adjusting range: *1 ~ 0 ~ *1;
Measuring resolution: 0.***1;
Measurement accuracy: 0.***5
Frequency output
Adjusting range: *0Hz ~*0Hz;
Output adjusting resolution: 1Hz, 0.1Hz, 0.*1Hz, or 0.**1Hz;
Resolution: 0.**1Hz;
Accuracy: 0.**2 Hz.
Harmonic setting
Harmonic order: 2nd ~*3rd
Harmonic amplitude: 0~*0%
Harmonic angle: 0°~**9.*9°
Harmonic set error: 2~*1times: ≤±0.1%, *2~*3 times: ≤±0.2%ï¼›
Energy error measurement:
Active energy basic error limit:
±0.*5%RD (Voltage *5V~**0V, Current 0.*2A~**0A, PF≥0.5);
±0.1%RD (Voltage *5V~**0V, Current 0.*1A~0.*2A, PF=1);
Reactive energy basic error limit:
±0.1%RD (Voltage *5V~**0V, Current 0.*2A~**0A, PF≥0.5);
±0.2%RD (Voltage *5V~**0V, Current 0.*1A~0.*2A, PF=1);
 
Energy pulse
Input pulse: 3 channels active, 3 channels reactive
 
Other parameters:
Power supply:           *****5VAC/DC
Power frequency:        *0Hz~*0Hz
Power consumption:       *0VA~***0VA
Environment condition:          *0℃~*0℃,Humidity: RH≤*5%
Storage environment:     **0℃~*0℃
Size:                   **0mm(Lï¼‰× **0mm(Wï¼‰× **6mm(H)
Weight:                    *5kg
 
 
 
 
 
 
 
 

 
 

Pays: China
N ° de modèle: MTS-100
Prix FOB: Obtenir le dernier prix
Localité: -
Prix de commande minimale: -
Commande minimale: -
Packaging Detail: -
Heure de livraison: -
Capacité de Fournir: -
Payment Type: -
Groupe de produits : -

Send a direct inquiry to this supplier

To:

Diana < Kongter Test & Measurement Co. Ltd >

Je veux savoir: