B.O.D. Incubators are used to provide temperature conditions for
Bio-Oxygen Demand test for cells / tissue culture / bacteria
micro-organism culture application, raw material and bulk product
storage, plasma and blood product storage, serum incubation,
immunological studies and other applications in the field of
research, development, production and quality control.
EIE incubators are majorly used for Media Preparation & Culture
growth at temperatures of *2.5°C (±2.5°C) & *2.5°C (± 2.5°C) in
Microbiology or ARD labs across the world.
Salient Features
·   Exterior boy is fabricated from Mild Steel
material, which is powder coated in attractive shades.
·   Interior chamber is also fabricated from Mirror
polished Stainless Steel S.S. - **4 Material
·   Outer double walled metal door with sponge -
type silicon gasket for air-tight sealing as to avoid leakage of
chamber uniformityÂ
·   Electrical wiring as per CE Compliances - with
 individual numbering of each internal circuitry wire for ease
of maintenance & Repairing
·   Chamber illumination is accomplished by
Fluorescent light with door switch.Â
·   Cord wire duly tested and inspected with stress
factor as per CE standardÂ
·   Electric Motor of blower located at the back
side of  unit, which is protected with safety cover to avoid
accidentÂ
·   Standard motor of reputed companies - such as
CG, GODREJ or GE Make
·   User friendly and tactfully designed chamber
door and locking mechanism
·   Aesthetic outer appearance and high
qualityÂ
·   Unit mounted on castor wheels for easy
movement.Â
·   Supplied complete with Stainless Steel Trays
for sample placement
·   Supplied complete IQ, OQ, PQ, DQ Documentation
and instruction manual.
Technical Specifications
·   Construction     Â
         :
 Double walled
·   Interior     Â
        Â
     :  S.S. - **4 Grade mirror
polished Stainless steel material
·   Exterior     Â
        Â
    :  Mild steel material, which is
powder coated in attractive shades
·   Inner working size    Â
     :  *0 x *0 x *0 cm (H x W x
D)
·   Chamber volume    Â
      :  *4 Liters
·   Thermal Insulation    Â
    :  PUF insulation to avoid thermal
loss (B/w Inner chamber and exterior body)
·   Insulation thickness   Â
    :  *0 mm
·   Insulation source    Â
      :  Imported from
"Huntsman USA"
·   Temperature Range    Â
   :  5 °C to *0 °C
·   Temperature Resolution    :
 0.1 °C
·   Temperature Accuracy   Â
  :  ± 0.1 °C
·   Temperature Uniformity    :
 ± 0.2 °C
·   Temperature Control    Â
  :  By Micro-processor based Auto-tune PID
Digital Temp Indicator cum Controller
·   Temperature Display    Â
  :  LED Display
·   Temperature Sensor    Â
   :  High quality PT - **0 Sensor
·   Illumination     Â
         :
 Fluorescent Tube lightÂ
·   Tube Light Make    Â
      :  GELCO
·   Fluorescent light watts   Â
  :  *1 Watts
·   Heating source    Â
        :
 U-shaped S.S. Tubular heaters
·   Heater watts     Â
        :  **0
Watts
·   Blower     Â
        Â
     :  For Forced Air
circulation
·   Motor of Blower    Â
      :  Marathon/GE/Any
other reputed make
·   No. of trays     Â
        Â
 :  *1 Numbers
·   Refrigeration    Â
         :
 CFC free EMERSON compressor utilizing R***4a eco friendly
refrigerant
·   Observation     Â
         :
 Inner transparent acrylic door for quick viewing and
retrieval
·   Door lock     Â
        Â
   :  Ergonomic and secured key lockable door
lock
·   Feet  on    Â
        Â
     :  Castor wheels (For easy
mobility)
·   Electrical     Â
        Â
   :  **0 Volt, *5A, *0 Hz, AC Supply
Air Circulation
Temperature is maintained by a quiet running blower for better air
circulation throughout the chamber. Â Forced air circulated
vertically down and re-circulated throughout the chamber for
uniform temperature distribution.
Heating & Cooling System
Long lasting U-Shaped tubular heaters used as heating element.
Hermetically sealed compressor CFC free compressor (**4 A gas)
coupled with evaporation coil and condenser.
Trays for samples
·   Removable wiremess trays are part of the
standard supply.
·   The trays of the incubator will be manufactured
from strong Stainless steel rods - strong enough to
 with-stand heavy load of test specimens, which should be
equally distributed among trays.Â
·   Such trays will also facilitate better air
circulation.
·   The distance between trays will be ****0
centimeters.
Safety Features
·   High temperature safety cut off
(Thermostat)
·   Electrical overload safety (Fuse *0
Amperes)
·   Time delay for compressor switch ON
Pre installation mandatory requirement : (Guarantee void in case of
non compliance)
a)Â Â Â An operator shall maintain Room temperature
around machine preferably at *5 °C with air conditioning system or
shall arrange for a well ventilated room with exhaust fan. However,
surrounding temperature should not exceed *0 °C .
b)Â Â Â Stabilized Input Voltage of **0 Volt, *0 Hz,
 *0 Amps, AC Supply must be available for error less
performance of the instrument. Use of Servo Controlled Stabilizer
is recommended.
Optional Accessories At extra cost
1)   On site validation    Â
        Â
        Â
     @********************   Additional tray    Â
        Â
        Â
       Â
Pays: | India |
N ° de modèle: | - |
Prix FOB: | Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | - |
Packaging Detail: | - |
Heure de livraison: | - |
Capacité de Fournir: | - |
Payment Type: | - |
Groupe de produits : | PHARMACEUTICAL TESTING INSTRUMENTS |