Product introduction
Three terms remote monitoring and controlling, automatic control
series products
Tech parameters
Â
A,Manual control panel(standard configuration)provide the basic
start/stop with following configurations and
functions:
1,start/stop controller
2,three phase current meter
3,voltage meter and selection switch
4,frequency meter/water temperature gauge/oil pressure gauge/ time
recorder/voltage meter of battery
5,emergency stop
6,Alarm function: over speed, high water temperature, low oil
pressure, charging failure
7,Protection function: low oil pressure, high water temperature,
over speed, emergency stop and other protections.
B,Self-start control panel under electric supply off(voltage loss).
Besides the configuration and function of standard manual control
panel, this control panel appends remote control
interface.Â
1,automatic /stop/manual function selection
2,time-delay relay for starting (**5seconds,
adjustable)
3,time-delay relay for
stopping(0~**0seconds,adjustable)
4,three times self starting time relay
5,city electric charger
6,Added alarm function:low/over speed, output voltage failure,
start failure, high water level alarm, emergency
stop
7,Added protection function: low/over speed, output voltage
failure(over voltage, under voltage, over current), start
failure,
C,Full-automatic remote monitoring and controlling
panel.
1,LCD screen display the operating steps, status, failure and
operating parameters.
2,RS**2/**5 interface, remote monitoring and controlling, remote
measuring, remote signaling.
3,Gen sets protection, stop and alarm automatically in the
following circumstances: start failure, over speed, low speed, high
water temperature, low oil pressure, no signal from speed sensor,
charging failure, etc.
D,Automatic load switching screen(ATS)
1,four pole, mechanical/electric interlock switch.
2,indicator of electric supply, electricity generating and loading
status.
3,automatic/manual selector switch.
4,acid pickling, phosphorization, spray-paint treatment of the
screen.
5,Reserved space for and output cable.
6,auto switching time no more than 7second,
(adjustable)
E,Unattended operation. If client require, the independent full
automatic control panel can provide independent control cabinet
which unify the self-start control function and automatic load
switching function, operate conveniently, and suitable for
centralized management of all electrical
equipment.
F,Parallel operation control panel
1,manual/half-automatic/full-automatic two sets or more sets
parallel operation
2,Many sets parallel to power grid, more reliable on power
supply.
3,centralized dispatching, distributes load automatically, easy to
maintain and repair.
4,More economical efficiency, can operate the sets according to
actual requirements, saving oil.
5,More flexible for the future, can add more equipments to meet the
requirement of adding load. Â
Â
Â
Detailed function of automatic generator sets
1.      Self-start and
self-operation function.
Automatic/manual ATS switch on the control cabinet, the switch
should be on automatic at emergency mode. When city power fails or
lower than the *0% of rated voltage, the generator sets will start
automatically within *5s, and if continuous 3 times start failure,
it will alarm sound and light.
2.      Self-stop
function
During the automatical operation, if the city power recovers and
confirmed for 5 seconds, the generator sets will stop operation
automatically. First cut off the load, and the city power will
recover to work, at this time, the generators sets will work at
idle speed, and 3mins later, it will stop. During the 3 mins, if
the city power fails again, the generator sets will return to work
again.
3.      Self-protection
function
If the generator sets get 3 starting failures, the control cabinet
will lock the system and alarm sound and light. During the
operation, if faults like high oil temperature, low oil pressure,
over speed, under frequency, under voltage, etc, the generator sets
will emergency shutdown.
Self-charging function
The generator sets will charge the battery automatically no matter
by the city power or by itself. The charging system choose
switching power, it will charge in two steps, first when the
battery capacity is lower, it will charge at constant current of
6ADC, and when the voltage of the battery arrive *6.5v, it will
change to charge at constant voltage, and keeps floating charge
.The charging will stop when battery is full.
4.      Manual
operation
The controlling system of the generator sets is interlocking
designed by manual and automatic. When the generator sets operate
under manual mode, it can control the start and stop, high/low
speed, alarm test, alarm reset, breaker on/off of self-generating,
etc. Emergency shutdown will work in both states. This
only under emergency state.
Pays: | China |
N ° de modèle: | - |
Prix FOB: | ( Negotiable ) Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | 1 |
Packaging Detail: | standard exporting package |
Heure de livraison: | 7-10days |
Capacité de Fournir: | 10 Set per Month |
Payment Type: | Western Union, L/C, T/T |
Groupe de produits : | - |