For low myopia MCT Technology high technology By Wuhan Web Science&Technology Development *****,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
For low myopia MCT Technology high technology
Next

For low myopia MCT Technology high technology

262 ~ 270 / Piece

|

1 Piece Minimum Order

Pays:

China

N ° de modèle:

New design

Prix FOB:

262 ~ 270 / Piece Obtenir le dernier prix

Localité:

China

Prix de commande minimale:

262 per Piece

Commande minimale:

1 Piece

Packaging Detail:

one piece in a plastic dry case, as customer required

Heure de livraison:

5days

Capacité de Fournir:

1000 Piece per Month

Payment Type:

PayPal, Western Union, T/T

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Jiangqiao

Jianghan Road, Wuhan, Hubei

Contacter maintenant

Spécification du produit

  • Color:Purple/Brown/Gray/Blue

La description

Dynamic analysis the changes of ocular axial length of different types of myopia.

WU gang-yue HUANG tang-qin.Jinhua Eye Hospital, Jinhua *****0

ABSTRACT 

ObjectiveDynamic analysis the changes of ocular axial length of different types of myopia(low Myopia group and moderate myopia group, low age group and high age group) after orthokeratology.

MethodsSelect *3 adolescents of wearing MCT Tech Design ortho-k lens in our hospital from ***9 to ***2,male *8, female *5, a total of **1 eyes, ranging in age from 8 to *4 years old,diopter degree≤ *6.*0D, with-the-rule astigmatism≤ *1.*0D, against-the-rule astigmatism≤*0.*5D. To observe the changes of ocular axis after 1 week, 1 month, 3 months, 6 months, *2 months, *8 months, *4 months of wearingOrtho-K contact lensthrough overnight wear. The volunteers were divided into 4 groups: low myopia group ( the Diopter degree≤ *3.*0 D ) and moderate myopia group (*3.*0D ~ *6.*0 D ); low age group ( 8 to *0 years old ) and aged group( *1~ *4 years old ). This grouping was according to the degree of myopia and age.

ResultsThe growth of ocular axis after six months of wearingOrtho-K was statistically significant compared with unwearing ( t=4.*8, P0.*5).

ConclusionsThe effect of wearing MCT Tech ortho-k contact lens of controlling myopia is better for Moderate myopia than low myopia, while the factor of age has no effect on controlling myopia.

  [Key words]  Orthokeratology ; myopia control ;axial length  

 

Along with the increasing incidence of juvenile myopia, and the appearance in younger ages, more and ophthalmologists select effective way to control myopia. Orthokeratology is accepted by ophthalmologist in both domestic and abroad, but we clinically found that for ortho-k lens, its effect is uneven for different patients. For some wearers, their eye axis changes is little for a year or two years later, but for some wears, after a few months later, the axial became significantly longer and whether there is any objective factors, such as age, diopter, and so on? Now, we will show the treatment effect and the axis reports from our hospital for 3 years.

 

SUBJECTS & METHODS

1.Clinical Data

Selected from *3 cases teenagers who firstly wear Ortho-k lenses for over 2 years in ***9 to ***2. There are totally **1 eyes and male *8 cases and female *5 cases. The first wearing is from 8 ~ *4 years old, and the average age is *0.*7± 1.*0. The diopter of spherical power is - 6.*0 D or less, the inverse rule astigmatism is - 1.*0 DC, and the rule astigmatism is - 0.*5 DC or less.

According to the degree of myopia, the wearers were divided into low myopia group whose spherical power was - 3.*0 D or less and there were totally *8 eyes;

Moderate myopia group whose spherical power was 3.*0 D ~ 6.*0 D, and there were totally *3

According to the first wearing age, there was young age group ***0 years old which hadtotally *2eyes;

And older age group which is in *1 ~ *4 years old and totally *9 eyes.

2.Methods

(1) According to the standard fitting process of Ortho-k lens, all cases include the naked eye eyesight test, medical optometry correction, corneal topography curvature test, IOL Master, corneal thickness test, eye disease screening programme, such as slit lamp examination, non-contact intraocular pressure, retinal examination. (2) After excluding all contraindications, customized the lens according to the results of the corneal topographic map and the result of medical optometry. (3) Guide patients to wear and maintain lens, and ask patients strictly under the wearing time: wear 8 ~ *0 hours at night. Discuss with parents to and pay special attention to the clean and health. After wearing lens 1 day, 1 week, 1 month, 3 months, 6 months, *2 months, *8 months and *4 months, to do the recheck. The contents are the eyesight, eye axis, corneal topographic map, diopter, corneal thickness, intraocular pressure; Palpebral conjunctiva and bulbar conjunctiva, cornea transparency, damage, and phenomenons such as tears. If you feel unwell or have any abnormal, do the timely treatment, and stop wearing for a few days which are determined by the physician.

3. Materials & Equipment

The material of the lens is the third generation of Ortho-k lens, Boston XO whose DK value is **0. The lens is provided by E&E company in the United States; the lens is use reverse geometric four arcs design, and it total diameter is 9.*0 ~ *1.*0 mm. The lens is designed by Professor Wang in Shanghai Furen ophthalmic hospital. This lens is Ortho-k Leans designed by new digital model technology, and we also call it MCT lens. The lens greatly improved the traditional Orthokeratology, mainly used corneal shape, and make the cornea gradually to a more rational deformation, and finally help us to achieve the effect of safe vision correction, MCT lens, MCT technology provided by Wuhan Web Science and Technology Development Co., LTD and the measurement of eye axis is by IOL-master optical measurement instrument from Chua's Company.

4. Statistical Methods

Use SPSS*9.0 test statistical software to do statistical analysis, and put P < 0.*5 as difference. And then, there is statistical significance.

RESULT

1.For all the wearer, after wearing for 1 week ~ 1 month, the naked eye vision basically recovered to 1.0; The eye axis changes before and after wearing, and the increase of eye axis is statistically significant. But 1 week and 1month after wearing, if eye axis became slightly shorter, the difference will be with statistically significant. Shown in table 1.

Table 1The comparison of eye axis before and after wearing Lens (mm)

 

 

Before Wearing

1Week

1Month

3 Months

6 Months

*2Months

*8Months

*4Months

Eye Axis

*4.8±0.*7

*4.*9±0.*8

*4.*8±0.*7

*4.*1±0.*6

*4.*9±0.*5

*4.9±0.*7

*5.0±0.*7

*5.1±0.*8

Axis Growth

 

*0.*1±0.*4

*0.*2±0.*6

0.**7±0.*9

0.**7±0.*6

0.**3±0.2

0.*5±0.*4

0.*6±0.*7

T Value

P Value

 

t=*4.*0

P=0.*0

t=*4.*7

P=0.*0

t=0.*5

P=0.*5

t=4.*8

P=0.*0

t=8.*8

P=0.*0

t=*1.*4

P=0.*0

t=*1.*5

P=0.*0

 

2.Grouped by different degrees of myopia, there was eye axis changes comparison: low myopia and moderate. One month after wearing, there were eye axis growth differences. It was statistically significant. For moderate myopia group, its axis was obviously slower growth. Shown in table .

Pays: China
N ° de modèle: New design
Prix FOB: 262 ~ 270 / Piece Obtenir le dernier prix
Localité: China
Prix de commande minimale: 262 per Piece
Commande minimale: 1 Piece
Packaging Detail: one piece in a plastic dry case, as customer required
Heure de livraison: 5days
Capacité de Fournir: 1000 Piece per Month
Payment Type: PayPal, Western Union, T/T
Groupe de produits : New design contact lenses

Send a direct inquiry to this supplier

To:

Mr. Jiangqiao < Wuhan Web Science&Technology Development ***** >

Je veux savoir: