Fire alarm control panel By Warningfire Company Limited,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Fire alarm control panel
Next

Fire alarm control panel

|

- Minimum Order

Pays:

China

N ° de modèle:

WA

Prix FOB:

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Heure de livraison:

-

Capacité de Fournir:

-

Payment Type:

T/T, PayPal

Groupe de produits :

-

Contacter maintenant
Membre gratuit

Personne à contacter john

Jinlu Industrial Zone, Wenzhou, Zhejiang

Contacter maintenant

Spécification du produit

  • Brand Name: WARNINGFIRE

La description

Fire control panel WA Series is available in 1,2,4,6, 8 or *6 zone sizes.
Housed in a light grey flame retardant ULV0 enclosure, designed to meet modern architectural surroundings, with a removable hinged door. The SX has been designed with ease of installation in mind, in addition to the robust electronic design expected from king fire alarm.
 

Technical Data
 

The unit somes with 2 sounder circuits , a fault relay, fire relay and a Class Change . It has sounder delay and zone disable facilities, and has a 1 man test mode.

. Complies fully to EN*4 Pt 2 & Pt 4
. Microprocessor based
. Built in detector removal line integrity (no need for active E.O.L.)
. Space for up to 2 x 7AH *2V SLA Batteries
. Battery charger short circuit protection
. Zone short circuit protection
. Fire change over relay output
. Fault change over relay output
. Class Change
. Top, Bottom & Rear Cable Entries
. Zone isolate facility
. One man test Facility
. Front Panel Short circuit indication
. Programmable External Sounder delay (**9 minutes in 1 minute increments)
. Earth fault indication . Front panel delay override facility
. Suitable for surface & semi-flush installation
. CE Marked
. Meets the latest European low voltage directive
. Battery overcharge thermal protection
. IP *3
 

The unit somes with 2 sounder circuits , a fault relay, fire relay and a Class Change . It has sounder delay and zone disable facilities, and has a 1 man test mode.

. Complies fully to EN*4 Pt 2 & Pt 4
. Microprocessor based
. Built in detector removal line integrity (no need for active E.O.L.)
. Space for up to 2 x 7AH *2V SLA Batteries
. Battery charger short circuit protection
. Zone short circuit protection
. Fire change over relay output
. Fault change over relay output
. Class Change
. Top, Bottom & Rear Cable Entries
. Zone isolate facility
. One man test Facility
. Front Panel Short circuit indication
. Programmable External Sounder delay (**9 minutes in 1 minute increments)
. Earth fault indication . Front panel delay override facility
. Suitable for surface & semi-flush installation
. CE Marked
. Meets the latest European low voltage directive
. Battery overcharge thermal protection
. IP *3
 


Pays: China
N ° de modèle: WA
Prix FOB: Obtenir le dernier prix
Localité: -
Prix de commande minimale: -
Commande minimale: -
Packaging Detail: -
Heure de livraison: -
Capacité de Fournir: -
Payment Type: T/T, PayPal
Groupe de produits : -

Send a direct inquiry to this supplier

To:

john < Warningfire Company Limited >

Je veux savoir: