FINGERTIP PULSE OXIMETER
Next

FINGERTIP PULSE OXIMETER

|

500 Unit Minimum Order

Pays:

Turkey

N ° de modèle:

AC 601

Prix FOB:

Localité:

China

Prix de commande minimale:

-

Commande minimale:

500 Unit

Packaging Detail:

We load on trucks safely.

Heure de livraison:

EXW

Capacité de Fournir:

5000 Unit per Year

Payment Type:

T/T, L/C

Groupe de produits :

-

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Mert

Osmangazi mahallesi, Istanbul, Esenyurt

Contacter maintenant

Spécification du produit

  • Color:White
  • Product code:AC 601
  • Screen:LED

La description

Theprincipleofpulseoximeterisbasedontheredandinfraredlightabsorptioncharacteristicsof oxygenatedanddeoxygenated hemoglobin.Oxygenated hemoglobin absorbs more infrared light and allows more red light to pass through (Figure 1). Deoxygenated (or reduced) hemoglobin absorbs more redlightandallowsmoreinfraredlighttopassthrough.Redlightisinthe******0nmwavelengthlight band.Infraredlightisinthe*******0nmwavelengthlightband. Pulse oximeter sensors have red and infrared low voltage light emitting diodes (LEDs) wich serve as light sources. The emitted light is transmitted through the tissue, then detected by the photodetector and sent to the microprocessor of the pulse oximeter. All constituents of the human body, venous and arterial blood, and tissue absorb light (Figure 2). The pulsating of arterial blood results in changes in the absorption to to added hemoglobin (Hb) and oxygenated hemoglobin (HbO2) in the path of the light. Since HbO2 and Hb absorb light to varying degrees, this varying absorption is translated into plethysmographic waveforms at both red and infrared wavelengths. The relationship of red and infrared plethysmographic signal amplitude can be directly related to arterial oxygen saturation.
Dear users, thank you very much for purchasing the Pulse Oximeter. This manual contains the instructions necessary to operate the product safely and in accordance with its function and intended use. Observance of this manual is a prerequisite for proper product performance and correct operation and ensures patient and operator safety.
(RED) **0nm
(INFRARED) **0nm
**0 **0 **0 **0 ***0
*2
*1
0
1
WAVELENGTH(nm)
EXTINCTION(*0X)
HbO2
Hb
IR Led Red Led
PhotoDiode
Figure 1  Absorption spectra of HbO2 and Hb for red and infrared wavelengths
Figure 2 Oximeter's schematic illustration

Pays: Turkey
N ° de modèle: AC 601
Prix FOB: Obtenir le dernier prix
Localité: China
Prix de commande minimale: -
Commande minimale: 500 Unit
Packaging Detail: We load on trucks safely.
Heure de livraison: EXW
Capacité de Fournir: 5000 Unit per Year
Payment Type: T/T, L/C
Groupe de produits : -

Send a direct inquiry to this supplier

To:

Mr. Mert < ABC TIP SAGLIK SPOR MALZ TEKS LIMITED COMPANY >

Je veux savoir: