Prix FOB
Obtenir le dernier prix( Negotiable )
|10 Piece Minimum Order
Pays:
China
N ° de modèle:
FEP
Prix FOB:
( Negotiable )Obtenir le dernier prix
Localité:
-
Prix de commande minimale:
-
Commande minimale:
10 Piece
Packaging Detail:
-
Heure de livraison:
15
Capacité de Fournir:
100000
Payment Type:
-
Groupe de produits :
Personne àcontacter Ms. Judy
#80 Zhonghuaxi Road,Ganjingzi District,Dalian, China, Dalian, Liaoning
 Teflon®FEP gas sampling bag with PTFE straight valve & septum port syringe sampling FEP*1_0.5L(air sample bags)
   Teflon®FEP Gas Sampling Bag is made of Polyperfluorinated Ethylene Propylene(F*6),film thickness is about 0.*7 mm(called Teflon FEP by DUPONT USA).FEP film is the most chemically resistant film in the fluoropolymer family,low adsorption.The melting temperature of FEP film is **0℃,so the difficulty of sealing for FEP is far greater than PVF(Tedlar) and PVDF(Kynar),our company successfully resolved the problem of difficulty heat seaing for FEP in ***3.
   Teflon®FEP is one of the most chemically inert materials for making gas sampling bags. It works well in extreme temperatures ranging from **0° to **0°F; allowing it to be used in most stack sampling conditions. *-mil FEP film is completely resistant to the most severe corrosives. Relatively low permeability results in minimal sample loss. FEP bags can be specified for applications involving rough handling.
Features:
• very low permeation
of gases through the wall of the bags
• superb resistance to chemicals,strong acid,strong alkali,strong
corrosion and organic solvent,low adsorbability.
• water vapor osmotic quantity is 1.3g/m2.*4h.0.1Mpa, oxygen
osmotic quantity is ***0cc/m2.*4h.0.1Mpa(the data is the measured
value,not the guarantee value)
• Standard
Teflon®FEP Gas Sampling Bag Sizes:
0.5L,1L,2L,3L,4L,5L,8L,*0L,*5L,*0L,*0L,and
*0L~***0L or customized size.
Select from a variety
of sizes to suit your needs.
Â
Specification |
---|
 Product Type |  Sampling Bag |
 Material |  FEP |
 Volume(Liters) |  0.5 |
 Model |  FEP*1_0.5L |
 Brand |  Hede |
Â
  Teflon®FEP Gas Sampling Bag is suitable for high accuracy PPM and PPB analysis sampling, it can collect and save all kinds of strong corrosive and high chemical activity of gaseous,liquid samples and VOCs samples. Our FEP gas sampling bags are available with different valves and fittings and can meet a wide range of applications in environmental protection industry.
Operating
guide:
• Inflation
pressure:: Avoid filling pressure higher than ***0Pa. Fill gas
until the bag is fully expanded, however, it is not so tense when
you press it using your finger.
• Operating temperature:: Working temperatures should be **0°C to
***0°C for PTFE connector and **0°C to **0°C for stopcock valve
.
• Storage and use:: Keep away from flame and high temperature
when filling and storage. Avoid contacting sharp
stuff.
•Gas
exchanging:: Before use, flush sampling bags three times with the
gas you want to fill.
•Needle
sampling:: When using a needle to draw gas from highly elastic
septum, squeeze the septum with fingers in order to restore the
sealing property after pulling out the needle.
Precautions:
•The sample gas
in sampling bag to save time should not be too long,specific
saving time depend on detection limit of experimental analysis
requirement,gas component species,temperature and
humidity,pressure,etc:generally,for pure inert gas,sampling bag
can be used as a temporary storage container and recommended
storage time less than *2 hours;for standard gas,flue gas,ambient
atmosphere,recommended storage time less than *4
hours.
•The gas
sampling bag should be cleaned repeatedly replacement if it is
reused. Suggest the same sample bag collecting samples of the
same kind gas, don't mix.
•High purity
nitrogen gas heating replacement can reduce the interference of
organic deposition
•Avoid filling pressure higher than ***0Pa, fill gas until the
bag is fully expanded, however, it is not so tense when you press
it using your finger.The overpressure filling can cause gas
sampling bag burst damage.
•When sampling
and cleaning,please do not exceed *0% of the calibration
volume,take 1L sampling bag for example,suggest sampling volume
is less than 0.8 L.
• There must be
a blank sample compare for precise experimental analysis to do
background deduction.
• For high-temperature high-pressure gas should be down to normal
temperature and pressure to sample,specific treatment method
according to actual situation.
• For negative pressure gas, should be sampled by appropriate
power and flow rate vacuum pump.
• For the gas containing particulate matter,dust and
aerosols,should adopt filter to prevent polluting the sample
bag,then difficult to clean.
Packaging &
Shipping:
• Reply your
inquiry within *4 hours
•
Experienced staffs answer all your questions in fluent
English
•
Exclusive and unique solution can be provided to our customer by
our well-trained and professional engineers and
staffs.
•
Special discount and protection of sales area provided to our
customers
Pays: | China |
N ° de modèle: | FEP |
Prix FOB: | ( Negotiable ) Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | 10 Piece |
Packaging Detail: | - |
Heure de livraison: | 15 |
Capacité de Fournir: | 100000 |
Payment Type: | - |
Groupe de produits : | FEP Gas Sampling Bag |