Product Name
:
|
Smart Professional Child/Baby infrared thermometer AOJ-20B
|
  Applicable
Regulations and lawsÂ
|
ASTM E-1965-98(Reapproved 2009) standard specification for
Infrared thermometers for intermittent determination of
patient temperature
|
ISO80601-2-56 first edition 2009-10-01 medical electrical
equipment -part 2-56: particular require-ments for basic
safety and and essential performance of clinical
thermometers for body temperature measurement.(general
plastic surgery/general hospital)
|
Advantage
|
1> Magnetic Probe Cover With Filter
Automatic Modes Switch Between Forhead & Ear
Mode,Will avoid the mode mistakeÂ
|
2> Child age divided into 3 stages (3month-2.5 years old
,2.5 years -6 years old,above 6 years old )Which make the
measurement more accurate .
|
3> Object mode sets a separate round to avoid the
wrong mode
|
4> Both sound and backlight fever warning
|
5> Support mute/un-mute measurement.
|
Certifications/Award
|
US FDA, Shape Patent, Product Invention Patent,IF Design
Adword
|
Display
|
Segment LCD dispaly, 4-Color LED backlight
(White/Green/Orange/Red)
|
Temperature Units
|
°C/°F ,Switchable
|
Power SupplyÂ
|
DC 3V,AAA*2Â
|
Measurement Range
|
Forehead: 32°C-42.9°C(89.6°F-109.2°F)
|
Ear: 32°C-42..9°C(89.6°F-109.2°F)
|
Object: 0°C-100°C(32°F-199°F)
|
Accuracy(Laboratory)
|
Ear&Forehead mode +-0.2°C/+-0.4°F
|
Object mode +-1°C/+-2°F
|
Display Resolution
|
0.1°C/°F
|
Automatic Shut Down
|
10s+_1s
|
Memory
|
40 Groups of temperature records
|
Operational Conditions
|
Temperature:10°C-40°C
(50°F-104°F)/Humidity:15%-95%RH,non-condensing atmospheric
pressure:70-106kPa
|
Storage Condition
|
Ambient temperature:20°C-55°C(-4°F-131°F)relative humidity:
0-95% RH,non-condensing atmospheric pressure :50Kpa to
106Kpa
|
Battery
|
2*aaa,can be used for more than 3000 times
|
Gross Weight&Dimension
|
93g(with Battery)163.5*40*41mm
 Product Name
:
|
Smart Professional Child/Baby infrared
thermometer AOJ-20B
|
  Applicable
Regulations and lawsÂ
|
ASTM E-1965-98(Reapproved 2009) standard
specification for Infrared thermometers for
intermittent determination of patient temperature
|
ISO80601-2-56 first edition 2009-10-01 medical
electrical equipment -part 2-56: particular
require-ments for basic safety and and essential
performance of clinical thermometers for body
temperature measurement.(general plastic
surgery/general hospital)
|
Advantage
|
1> Magnetic Probe Cover With
Filter
Automatic Modes Switch Between Forhead &
Ear Mode,Will avoid the mode mistakeÂ
|
2> Child age divided into 3 stages (3month-2.5
years old ,2.5 years -6 years old,above 6 years
old )Which make the measurement more accurate .
|
3> Object mode sets a separate round to
avoid the wrong mode
|
4> Both sound and backlight fever warning
|
5> Support mute/un-mute measurement.
|
Certifications/Award
|
US FDA, Shape Patent, Product Invention Patent,IF
Design Adword
|
|