Prix FOB
Obtenir le dernier prix|
1000 Piece Minimum Order
Pays:
China
N ° de modèle:
W81091
Prix FOB:
Localité:
CHINA
Prix de commande minimale:
-
Commande minimale:
1000 Piece
Packaging Detail:
10 tests/kit, bulk as reaquest, OEM.
Heure de livraison:
3 work days
Capacité de Fournir:
60000000 Piece per Month
Payment Type:
Other, PayPal, Money Gram, Western Union, D/P, D/A, L/C, T/T
Groupe de produits :
Personne àcontacter Ms. Yohey
No.1998 Yanggao Road, Shanghai, Shanghai
1. PRINCIPLE OF THE ASSAYÂ
Escherichia coli O**7 Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough Escherichia coli O**7 in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of Escherichia coli O**7 in the sample.Â
2. KIT COMPONENT
- *0×foil pouches, each containing one cassette, one pipette and a desiccant
- Product Manual
3. TEST PROCEDURE
- Incubation. Incubate the preenrich sample with enrichment broth, according to FDA suggested method or other well-established incubation method.
- Transfer 2 mL of incubated sample broth into a glass tube and boil for *0 minutes. Cool the samples to room temperature.
- Take out the cassette from the foil pouch and place it horizontally.
- Suck the boiled sample broth and drip 3 drops into the assay sample hole S.
- Interpret the result after *0 minutes. Result after *5 minutes is considered as invalid.
4.  INTERPRETATION OF RESULTS
Positive: The presence of both C band and T band, no matter T band is clear or vague.Â
Negative: Only clear C band appears.Â
Invalid: No colored band appears in C zone, no matter whether T band appears.Â
Â
5. STORAGE
The kit can be stored at room temperature (*-*0°C). The test kit is stable through the expiration date (*8 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight.
Pays: | China |
N ° de modèle: | W81091 |
Prix FOB: | Obtenir le dernier prix |
Localité: | CHINA |
Prix de commande minimale: | - |
Commande minimale: | 1000 Piece |
Packaging Detail: | 10 tests/kit, bulk as reaquest, OEM. |
Heure de livraison: | 3 work days |
Capacité de Fournir: | 60000000 Piece per Month |
Payment Type: | Other, PayPal, Money Gram, Western Union, D/P, D/A, L/C, T/T |
Groupe de produits : | Food Safety |