Prix FOB
Obtenir le dernier prix0 ~ 350
|1 Minimum Order
Pays:
China
N ° de modèle:
-
Prix FOB:
0 ~ 350 Obtenir le dernier prix
Localité:
-
Prix de commande minimale:
-
Commande minimale:
1
Packaging Detail:
-
Heure de livraison:
-
Capacité de Fournir:
1
Payment Type:
T/T, PayPal
Groupe de produits :
-
Personne àcontacter chengshan
Kaifeng, Henan
Main power | AC**0V *0HZ / DC*4V Â | |
Power consumption | <*5W (And set with sensor supporting power consumption ) | |
Display and push s | The big screen LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as alarm display ,four thin-film touch nubs ,which is used to data set . | |
Accumulator | Forward total quantity ,reverse total quantity | |
Output signal | Analog output | Bi-direction with two ways ,Isolation ***0mA/***0mA |
Load resistor:***0Ma;**1.5KΩ;***0Ma;****0Ω | ||
Frequency output | Forward & reverse flow output with frequency range set between *****0Hz.The external voltage must be lower than *5V and the max output and the max output current is *0Ma when the transistor is turned on | |
Alarm output | Two outputs from the collectors of photoelectric isolate transistors are for alarm signals .The external voltage must be lower than *5V and the max output current is **0Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty ,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits. | |
Pulse output | For pulse output in forward and reverse flow measurement ,upper frequency of pulse output can be up to ***0 CP/S relevant value of pulse is from 0.***1 to 1.0 M3/P .The width of pulse can be set to *0ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than *5 V and maximum output current is **0Ma when the transistor is turned on . | |
Accuracy | ±0.5% of the value displayed ,±0.3% or ±0.2% are selectable. | |
Damping time constant | Continuous varaiable from ****0 s (*0%)can be selected by group | |
Communication | RS**2 ,RS**5 or HART Communication are selectable ,with lighting resistance | |
Power failure | An anti-failure clock is designed in the flow meter which can save the power failure records for *6 times (*0 years) | |
Protection class | IP*5 | |
Ex-proof Mark | Exd[ia]ia‖Ct5 |
Pays: | China |
N ° de modèle: | - |
Prix FOB: | 0 ~ 350 Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | 1 |
Packaging Detail: | - |
Heure de livraison: | - |
Capacité de Fournir: | 1 |
Payment Type: | T/T, PayPal |
Groupe de produits : | - |