Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
ECG-1903 Industrial Conductivity Meter
Next

ECG-1903 Industrial Conductivity Meter

155 ~ 285 USD / Piece

|

3 Piece Minimum Order

Pays:

China

N ° de modèle:

ECG-1903

Prix FOB:

155 ~ 285 USD / Piece Obtenir le dernier prix

Localité:

China

Prix de commande minimale:

155 per Piece

Commande minimale:

3 Piece

Packaging Detail:

carton

Heure de livraison:

5 days

Capacité de Fournir:

6000 Piece per Month

Payment Type:

T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Charles

Shanghai, Shanghai

Contacter maintenant

Spécification du produit

  • measurement range:K=0.01, 0.1, 1.0, 10.0, 30.0
  • Resolution: 0.01 uS /cm, 0.01 MΩ
  • Precision:0.02 uS /cm, 0.01 MΩ

La description

ECG****3 Industrial online Conductivity Meter is developed on the basis of guaranteeing the performance and the functions. The clear display, simple operation and high measuring performance provide it with high cost performance. It can be widely used for continuous monitoring of conductivity of water and solution in thermal power plants, chemical fertilizer, metallurgy, environmental protection, pharmacy, biochemical engineering, foodstuff, running water and many other industries. FeaturesECG****3 series of microcomputer-based industrial control instruments are precision meters for measurementof conductivity or resistivity of solution. With complete functions, stable performance, simple operation andother advantages, they are optimal instruments for industrial measurement and control. The advantages of this instrument include: LCD display with back light and display of errors; automatictemperature compensation; isolated 4~*0mA current output; dual relay control; adjustable delay; alarming withupper and lower thresholds; power-down memory and over ten years of data storage without backup battery. According to the range of resistivity of the water sample measured, the electrode with a constant k = 0.*1, 0.1,1.0 or *0 can be used by means of flow-through, immerged, flanged or pipe-based installation.Technical Indexes1.Measuring range:0.1~**0 uS/cm (Electrode: K=0.1) 1.0~***0 us/cm (Electrode: K=1.0)*0~****0 uS/cm (Electrode: K=*0.0)0~*9.*9MΩ (Electrode: K=0.*1)2. Resolution: 0.*1 uS /cm, 0.*1 MΩ3. Precision: 0.*2 uS /cm, 0.*1 MΩ4. Stability: ≤0.*4 uS/cm *4h; ≤0.*2 MΩ/*4h5. Standard solution: Any standard solution6. Control range: 0~*9.*9mS/cm, 0~*9.*9KΩ7. Temperature compensation: 0~*0.0℃8. Output signal: 4~*0mA isolated protection output, Can double the current output.9. Output control mode: ON/OFF relay output contacts (two sets)*0. Relay load: Max. **0V, 5A(AC); Min. l l5V, *0A(AC)*1. Current output load: Max. **0Ω*2. Working voltage: AC **0V ±l0ï¼…, *0/*0Hz*3. Overall dimension: *6x*6x**0mm; dimension of the hole: *2x*2mm*4. Working condition: ambient temperature: 5~*5℃
Features

ECG****3 series of microcomputer-based industrial control instruments are precision meters for measurement
of conductivity or resistivity of solution. With complete functions, stable performance, simple operation and
other advantages, they are optimal instruments for industrial measurement and control.
The advantages of this instrument include: LCD display with back light and display of errors; automatic
temperature compensation; isolated 4~*0mA current output; dual relay control; adjustable delay; alarming with
upper and lower thresholds; power-down memory and over ten years of data storage without backup battery.
According to the range of resistivity of the water sample measured, the electrode with a constant k = 0.*1, 0.1,
1.0 or *0 can be used by means of flow-through, immerged, flanged or pipe-based installation.
 
Technical Indexes
1.Measuring range:
0.1~**0 uS/cm     (Electrode: K=0.1)
1.0~***0 us/cm    (Electrode: K=1.0)
*0~****0 uS/cm   (Electrode: K=*0.0)
0~*9.*9MΩ      (Electrode: K=0.*1)
2. Resolution: 0.*1 uS /cm, 0.*1 MΩ
 
3. Precision: 0.*2 uS /cm, 0.*1 MΩ
4. Stability: ≤0.*4 uS/cm *4h; ≤0.*2 MΩ/*4h
5. Standard solution: Any standard solution
6. Control range: 0~*9.*9mS/cm, 0~*9.*9KΩ
7. Temperature compensation: 0~*0.0℃
8. Output signal: 4~*0mA isolated protection output, Can double the current output.
9. Output control mode: ON/OFF relay output contacts (two sets)
*0. Relay load: Max. **0V, 5A(AC); Min. l l5V, *0A(AC)
*1. Current output load: Max. **0Ω
*2. Working voltage: AC **0V ±l0ï¼…, *0/*0Hz
*3. Overall dimension: *6x*6x**0mm; dimension of the hole: *2x*2mm
*4. Working condition: ambient temperature: 5~*5℃

Pays: China
N ° de modèle: ECG-1903
Prix FOB: 155 ~ 285 / Piece Obtenir le dernier prix
Localité: China
Prix de commande minimale: 155 per Piece
Commande minimale: 3 Piece
Packaging Detail: carton
Heure de livraison: 5 days
Capacité de Fournir: 6000 Piece per Month
Payment Type: T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal
Groupe de produits : EC

Send a direct inquiry to this supplier

To:

Charles < Shanghai Boqu EIT >

Je veux savoir: