DF-200 Dual-clamp Digital Phase Meter By Henan Defy Electronics Co. Ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
DF-200 Dual-clamp Digital Phase Meter
Next

DF-200 Dual-clamp Digital Phase Meter

|

- Minimum Order

Pays:

China

N ° de modèle:

-

Prix FOB:

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Heure de livraison:

-

Capacité de Fournir:

-

Payment Type:

T/T, L/C, Western Union

Groupe de produits :

-

Contacter maintenant
Membre gratuit

Personne à contacter Wu

Zhengzhou, Henan

Contacter maintenant

La description

I. Introduction

DF***0 Double Clamp Digital Phase Meter is special designed for voltage, current and phase tests, it is in high-precision, low price, portable hand-held, dual-channel  measuring. It's easy to measure the phase between U-U, I-I and U-I, identify the inductive circuit ,capacitive circuit and the phase sequence of three-phase voltage, detect the wiring group of transformer, test the secondary circuit and bus differential protection system, display the phase relationship among the CT groups of a differential protection system, and check if the wire of electric meter was correctly connected. When testing customers do not need cut off the tested current which  by slip core current transformer. When measuring the phase between U1 and U2, the two  circuit loop are completely isolated, so the possible misconnection is absolutely avoided, which may result in short circuit and may even burn the meter. The monitor of the device is high-contrast LCD screen, and the character in which could be as high as *5mm, and can be freely rotated approximately *0 °, which helps to obtain the best visual effects.
    The shell of the device is made of engineering insulating material, together with a rubbermade anti-vibration protection kits for safety and reliability.
II. Features & Functions

1. Withstand Voltage
    Parts between voltage  terminal and meter shell, parts between the iron core of the clamp-current transformer and secondary windings can stand ***0V/*0Hz. Parts between the two voltage  terminals can stand Sinusoidal AC Voltage **0V/*0Hz for 1min when testing.
2. Insulation Resistance
    Between meter circuit and meter shell, between the two voltage  terminals:≥*0MΩ.

III. Specifications

l Intrinsic Error

1. Reference Operating Conditions
(1) Temperature(*3±5)℃
(2) Moisture(*5~*5)% RH
(3) Wave forms of measured signal, sine wave β=0.*2
(4) Frequency of measured signal(*0±0.2)Hz
(5) Position of Measured current carrying conductor in the nipper jaw, Optional position
(6) Amplitude range of measured signal when measuring phase, **0~**0V, 0.5A~1.5A
(7) External reference frequency electromagnetic interference, Should be avoided

2. Limits of Intrinsic Error
    (1) AC Voltage(see Table 1)

Table 1 Error of AC Voltage

Measure range

Resolution

Limits of intrinsic error

*0V

0.*1V

±(1.2%RD*2)

**0V

0.1V

±(1.0%RD*2)

**0V

1V

±(1.2%RD*2)

Input Impedance:All the measure range is 2MΩ
    (2) Alternating current(see Table 2)

Table 2 Error of alternating current

Measure range

Resolution

Limits of intrinsic error

**0mA

0.1mA&a

Pays: China
N ° de modèle: -
Prix FOB: Obtenir le dernier prix
Localité: -
Prix de commande minimale: -
Commande minimale: -
Packaging Detail: -
Heure de livraison: -
Capacité de Fournir: -
Payment Type: T/T, L/C, Western Union
Groupe de produits : -

Send a direct inquiry to this supplier

To:

Wu < Henan Defy Electronics Co. Ltd >

Je veux savoir: