conventional fire alarm control panel
Next

conventional fire alarm control panel

|

200 Minimum Order

Pays:

China

N ° de modèle:

CK1000

Prix FOB:

Localité:

-

Prix de commande minimale:

-

Commande minimale:

200

Packaging Detail:

-

Heure de livraison:

15-30

Capacité de Fournir:

100000

Payment Type:

-

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Ms. Chloe

xixiang, Shenzhen, Guangdong

Contacter maintenant

Spécification du produit

  • color:red

La description

CHAPTER 1: Product Description
 
The CK***0 is a *-zone to **-zone FACP (Fire Alarm Control Panel), which uses conventional devices.  The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND**4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA***5 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad.  It also supervises all wiring, AC voltage and battery level.
 
This series of panels are basically the same in application and operation, their differences are shown in Table **1. CK***0 will be described as the example in the following sections.
 
Table **1
FACP Number of Detection Zones Number of Sounder Outputs Output Delay Settings
CK***4 4 1 N/A
CK***8 8 2 N/A
CK***6 *6 4 N/A

 
 
1.1 ProductFeatures
 
l      4,8,*6 Class B Initiating Device Circuits (IDCs)
✓   All zones accept conventional detectors and any normally open contact device
l      Four Class B Notification Appliance Circuits (NACs)
l      One Form-A Alarm Relay
l      One Form-A Trouble Relay
l      One Form-A Supervisory Relay
l      3.0 amps of system power
l      Max *0 conventional detectors in one zone.
l      Auto/Manual mode setting enable walk test.
l      Each Zone can be disabled,
l      Sound output can be disabled.
l      Manual active sound output enabled.
l      Able to report short and broken circuit of detection zones.
l      Designed with standby batteries and space provision for two sealed lead-acid batteries.
l      Testing and disable functions.

1.2 Specifications
 
AC Power
AC*****0 VAC, *0 Hz, 2.3 amps
Wire size: minimum #*4 AWG (2.0 mm2) with **0V insulation
Battery (lead acid only)
Maximum Charging Circuit: Normal Flat *—*@******************** Charger Capacity: *8 Amp Hour batter
Sound Output Device Circuits
General Alarm Zones 1 through *6
Operation: All zones Class B
Normal Operating Voltage: Nominal *4 VDC (ripple = **0 mV maximum)
Alarm Current: *5 mA threshold
Short Circuit Current: *2 mA maximum
Maximum Loop Resistance: **0 ohms
End-of-Line Resistor: 4.7K, ½ watt
Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone
Standby Current: 7.*6 mA
Three Relays Output
Relay contact rating: 2.0 amps

Pays: China
N ° de modèle: CK1000
Prix FOB: Obtenir le dernier prix
Localité: -
Prix de commande minimale: -
Commande minimale: 200
Packaging Detail: -
Heure de livraison: 15-30
Capacité de Fournir: 100000
Payment Type: -
Groupe de produits : fire alarm control panel

Send a direct inquiry to this supplier

To:

Ms. Chloe < Shenzhen Anogy Technology Co., Ltd >

Je veux savoir: