AES-1 (Aerosol Sensor
Unit)
Â
Â
Â
 |
- Particulates of 0.5 microns or
larger can be monitored.
- The aerosol sensor unit can be
used to keep optimum driving of filtering equipment related to a
clean room depending on actual condition of cleanliness
level.
|
FEATURES
Â
- Â Stable and sensitive
detection for Particulates of 0.5 microns and larger can be
monitored.
- Â Unique air sampling
method using "heater" to generate updraft, preventing choked flow.
Suction pump is not necessary.
- Â Long life laser. 20,000
h
- Â Compact size and low
cost.
Â
APPLICATIONS
Clean booth, Fan Filter Unit, Clean Unit etc Clean Room related
filtration system.
Â
SPECIFICATION |
Â
Light Source |
Semiconductor Laser |
Life (Light Source) |
20,000 h |
Detection Method |
Light Scattering |
Air Sampling Method |
Using "Heater" to generate updraft. Approx 0.1 L/m. |
Min. Detectable Size |
0.5 µ |
Detection Range |
100 ~ 100,000 pcs / 1 cf |
Operating Condition |
0
°C ± 40 °C 30 %RH ~ 80 %RH |
Output |
1
kHz Pulse Output |
Power Consumption |
300 mA |
Input Voltage |
DC12 V ± 10 % |
Dimension |
90
x 90 x 23 mm |
Weight |
Approx 120 g |
Â
 |
AES-1000Â (Aerosol
Monitor)
Â
Â
Â
 |
The
Aerosol Monitor which has easy-to-read display, and link to
Ethernet system, can materialize simplified monitoring of
Particulates at multiple location. |
Â
FEATURES
Â
- Â Stable and sensitive detection for Particulates
of 0.5 microns and larger. Easy-to-read air cleanliness level,
equivalent of ISO5 / Class 100 - ISO8 / Class 100,000.
- Â Unique air sampling method using "heater"
to generate updraft, preventing choked flow. Suction pump is not
necessary.
- Â Alarm comes on when the setting level
goes beyond the required cleanliness, while monitor gives alarm
signal output.
- Â Link to Ethernet system with purpose of
monitoring at multiple location.
- Â Long life laser. 20,000 h
- Â Compact and light, easy installation. Low
cost
|
Â
APPLICATIONS
Any place where you need simplified
cleanliness level monitoring
DISPLAY
Â
SPECIFICATION
Display |
10
x LED lights shows equivalent of Class 100 ~ Class 100,000
100(ISO5)-1,000(ISO6)-2,000-3,000-5,000-10,000(ISO7)-20,000-30,000-50,000-100,000(ISO8) |
Detection
method |
Light Scattering |
Sensor |
Shinyei AES-1 Aerosol Sensor |
Min. detectable
size |
0.5 µ |
Air Sampling
method |
Updraft airflow generated by built-in heater enables air sampling
of approx. 0.26 gal per minutes |
Cleanliness
Class |
From level of equiv. of ISO5 / Class 100 ~ ISO8 / Class
100,000 |
Alarm
Display |
Alarm LED light comes on when reaching to setting level |
Alarm
Output |
TTL open collector output in sync with alarm display |
Interface |
Ethernet x 1 port |
Power
Supply |
DC12 V ± 10 % 500 mA |
Operating
Temp/Humidity |
0
°C ~ 40 °C 30 %RH ~ 80 %RH |
Â
 |