2-18 Zones Conventional Fire Alarm Control Panel for Fire Alarm System By Shenzhen Usafe Intelligent Technology Co., Ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
2-18 Zones Conventional Fire Alarm Control Panel for Fire Alarm System 2-18 Zones Conventional Fire Alarm Control Panel for Fire Alarm System
Next

2-18 Zones Conventional Fire Alarm Control Panel for Fire Alarm System

40 ~ 100 / ( Negotiable )

|

1 Piece Minimum Order

Pays:

China

N ° de modèle:

YA-CP100

Prix FOB:

40 ~ 100 / ( Negotiable ) Obtenir le dernier prix

Localité:

Shenzhen

Prix de commande minimale:

40

Commande minimale:

1 Piece

Packaging Detail:

White product box + carton

Heure de livraison:

20-25 days

Capacité de Fournir:

20000 Piece per Month

Payment Type:

T/T, Western Union

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Ms. Sandy

Room 1002, Yingfeng Center Manjinghua Building, Nanlian, Longgang District, Shenzhen, Guangdong

Contacter maintenant

Spécification du produit

  • Usage:Conventional fire alarm system
  • Max. Protection Zones:18 zones
  • Material:Iron
  • Dimension:41.5 × 26.5 × 10cm

La description

Features:
External (key-switch operated):
  • Reset/resound/test zone lamps evacuate
  • Silence alarm sounders
  • Silence fault sounders
Internal:
  • One man detector test
  • Zone isolate
  • Revert to short-circuit: fire (no resistors in call points)
External indicators:
  • Sounder fault
  • Battery/power supply fault
  • Mains on
  • Zone fire
  • Zone fault
Internal indicators:
  • Open circuit zone fault
  • Short circuit zone fault
  • Zone isolated
  • Engineer test selected
Outputs:
  • Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)
Ancillary connections for expansion modules will allow the following:
  • Repeater panels
  • Multiple sounder outputs
  • Connection to landlord panel
  2 (0.8A supply) 4 / 6 (1.5A supply) 8/*0/*2/*4/*6/*8
(4.0A supply)
Power specifications   
Mains supply voltage **0±*0%V AC, *0/*0Hz **0±*0%V AC, *0/*0Hz **0±*0%V AC
*0/*0Hz
Internal power supply *7V DC *7V DC *7V DC
Total output current limited to **0mA at **0V AC ***0mA at **0V AC ***0mA at **0V AC
Auxiliary power output *7V DC *7V DC *7V DC
Mains supply monitored for failure Yes Yes Yes
Battery charger monitored for failure Yes Yes Yes
Batteries monitored for disconnection and failure Yes Yes Yes

Pays: China
N ° de modèle: YA-CP100
Prix FOB: 40 ~ 100 / ( Negotiable ) Obtenir le dernier prix
Localité: Shenzhen
Prix de commande minimale: 40
Commande minimale: 1 Piece
Packaging Detail: White product box + carton
Heure de livraison: 20-25 days
Capacité de Fournir: 20000 Piece per Month
Payment Type: T/T, Western Union
Groupe de produits : Fire Alarm Control Panel

Send a direct inquiry to this supplier

To:

Ms. Sandy < Shenzhen Usafe Intelligent Technology Co., Ltd >

Je veux savoir: