1.The more technical data of our ac/dc amp meter
Name |
precision |
normal specification |
remark |
|
ACÂ ammeter |
A |
1.5 |
0.***0A |
can be directly connected |
A |
1.5 |
*0/5A***0/5A |
secondary current passed by current transformer |
|
KA |
1.5 |
1KA**0KA |
secondary current passed by current transformer |
|
ACÂ voltmeter |
V |
1.5 |
*0V***0V |
can be directly connected |
KV |
1.5 |
1KV**5KV |
**0V secondary voltage passed by voltage transformer |
|
DCÂ ammeter |
µA mA |
2.5 |
*0μA***0μA 1mA***0mA |
can be directly connected |
A |
1.5 |
1A**5A |
can be directly connected |
|
A |
1.5 |
*5A***0A |
 outer attached shunt *5mV *0mV *0mV  |
|
KA |
1.5 |
1KA*3KA |
outer attached shunt *5mV *0mV *0mV  |
|
DCÂ voltmeter |
V |
1.5 |
3V***0V |
can be directly connected |
KV |
1.5 |
1KV*3KV |
outer attached resistance value |
|
Hz meter |
Hz |
2.5 |
****5HZÂ ****5HZ |
*6V.**0V.**7V.**0V.**0V |
Power meter |
KW.VAR |
2.5 |
**0VÂ **0VÂ ******0KV |
**0V secondary voltage passed by voltage ; Secondary current passed by current  transformer ***0KA/5A |
cosφ meter |
cosφ |
2.5 |
COSφ =0.****0.5 |
**0V/5AÂ **0V/5AÂ **0V/5A |
Â
1.Specification of ammeter for through current:0.1A 0.5A 1A 1.5A 3A 5A *0A *5A *0A *5A *0A *0A *0A *0AÂ
*5AÂ **0A,
Â
2. Specification of ammeter for transformation ratio:the meters should be used with a current transformer ofÂ
which primary current is *0A *5A *0A *5A *0A *0A *0A *0A *5A **0A **0A **0A...*0KA and externalÂ
secondary current 1A or 5A.As long as overload rate and the incoming current keep the same,dial scalesÂ
of all types in this series can be exchanged ye remain the accuracy.
Â
3.Overload rate of ammeters:1. non-overload 2. 1.2times 3. 2times  4. 5times.
Â
4.Specification of voltmeters for through voltage:*0V *0V *5V **0V **0V **0V **0V **0V **0V **0V **0VÂ
**0VÂ **0V.
5.Specification of voltmeters for transformation ratio:The meters should be used with a voltage transformer ofÂ
which primary voltage is **0V **0V **0V **0V ***0V ***0V ***0V ***0V ***0V...**0KV and externalÂ
secondary voltage **0V.
Â
6.Overload rate of voltmeters:1.non-overload  2. 1.2times.
Â
7.Product performance:all the meters are equipped with pure white silk- screen printing dial scale.The movement is made of intensive PBT plastics and high-performance magnetic materials so that it is vibration-resistant and heat-resistant.The case is made of ordinary ABS plastics of flame retardant ABS plastics,of which the resistant
 temperature can be up to *5°C.The base is made of PC plastics or flame retardant PC plastics,ofÂ
which the resistant temperature can be up to **0°C.The resistant voltage is higher than ***0V.
The resistant voltage is higher than ***0V.This kind of meter is easy to install with high-strengthen plastics grip piece by screwing down the nut so that the meter is of high immobility.
Â
8.Principles of measurement and the features:Each electromagnetic meter consists of a magnetÂ
coil with a static sheet iron inside and a moving sheet iron with a tractive balance spring.
When current flows through the magnet coil,magnetic field appears.Under such circumstance,theÂ
static and the moving sheet irons are magnetized simultaneously and remain the same polarity.
According to the theory that the same polarities repel each other,repulsive force between the twoÂ
irons makes the pointer deflect.When the torque and the restoring torque keep a balance,the staticÂ
and the moving sheet irons are magnetized simultaneously and remain the same polarity.
According to the theory that the same polarities repel each other,repulsive force between the two
 irons makes the pointer deflect.When the torque and the restoring torque keep a balance,the pointerÂ
on the moving iron will point to a scale mark,which is the measured value.
Â
9.The ellectromagnetic meters can be used for AC circuits under ordinary circumstance as well as for
 DC circuit instructed with TRMS.The structure of this kind of meters is simple,yet the accuracy is high,
as well,they can be used for *0/*0Hz circuit.Special frequency should be marked out when the order is placed.