Prix FOB
Obtenir le dernier prix20000 ~ 40000 / Set
|1 Set Minimum Order
Pays:
China
N ° de modèle:
MRD-FD6
Prix FOB:
20000 ~ 40000 / Set Obtenir le dernier prix
Localité:
Baoding ,China
Prix de commande minimale:
20000 per Set
Commande minimale:
1 Set
Packaging Detail:
wooden case
Heure de livraison:
25-30 days against the deposit or L/C
Capacité de Fournir:
40 Set per Month
Payment Type:
L/C, T/T
Groupe de produits :
Personne àcontacter Mr. Mery
No.118, Baoding, Hebei
1.*1KVÂ Generator
Neutral Grounding Resistors
There are six parameters needed to specify the neutral grounding resistor.
1. Rated voltage line to neutral or system voltage.
2. Rated fault current.
3. Rated duration time of the line to neutral voltage not exceeding the allowable temperature rise.
4. Rated Resistance.
5. Application environment, indoor or outdoor.
6. Enclosure material, ss plate or normal cold rolled sheet.
2.Standards Carried Out
DL/*******1  Neutral Grounding Resistance in Power Distribution
GB***0      Dry-Type Power Transformer
DL/T*******7  Overvoltage Protection and Insulation Co-ordination of AC Electrical Equipments
GB/T*********7  Experimental Technique of High Voltage
GB********7    Current Transformer
GB******3       Shell Protection Grade (IP code)
IEEE******2 Standard   Technique, Terms and Experiment of Neutral Grounding Device
GB**1.*****7    Insulation Co-ordination of Transmissional and Distributed Device of High Voltage.
DL/T*******6   Common Specifications for Purchasing High Voltage Switch Equipment.
GB*********1   Electrical Equipments Hand-over and Test Standard of Electrical Device Installation Project.
3.Notice for purchase
1. system rated voltage
2.short-time withstand current;
3. normal resistance;Â
4. with current transformer or not; transformation ratio, capacity and compound deviation of the current transformer;
5. method of wiring (optional): a. wire in from the top, and out at the bottom, b. wire in and out from the bottom, c. wire in and out from the side, d. wire in from the side and out at the bottom;Â
6. durable time for short-time withstand current;Â
7. material of resistance cabinet, protection grade of (IP), color code and installation site of the resistor cabinet;Â
8. with earthing record and temperature and humidity control equipment or not
Â
NGR Introduce  |
Neutral Grounding Resistors are used to protect power transformers, power generators and other associated equipment in your power systems against *0/*0 Hz faults (short circuit) and transient phenomena (lightning). |
SPECIFICATIONS   (Order Note)  |
There are six parameters needed to specify the neutral grounding resistor. 2. Rated fault current. 3. Rated duration time of the line to neutral voltage not exceeding the allowable temperature rise. 4. Rated Resistance. 5. Application environment, indoor or outdoor. 6. Enclosure material, ss plate or normal cold rolled sheet. |
Rang Parameters  |
• Rated current: from 1 amp to ***0 A • Rated voltage: from 0.4 to *5kV • Rated Resistance: from 1 ohm to ***0 ohm • Rated time: 1 sec to continuous time rating |
Technology Quality  |
with IEEE**2. Routine tests performed on each Neutral Grounding Resistor are measurement of resistance, high voltage power frequency, insulation measurement, aspect verification, dimensional control. Mingruis internal quality system has been developed and certified under ISO ***1 quality system |
Standard |
Standard unit includes the stainless steel resistor assembly plus all the required insulators, internal connections and hardware installed in a standard safety enclosure. Neutral Grounding Resistor units are completely assembled, prewired, and tested at our facility. For shipping all units are crated for added protection and ease of handling. |
Enclosure Options  |
•Stainless steel, cold rolled plate construction. Custom paint finish is available. |
Pays: | China |
N ° de modèle: | MRD-FD6 |
Prix FOB: | 20000 ~ 40000 / Set Obtenir le dernier prix |
Localité: | Baoding ,China |
Prix de commande minimale: | 20000 per Set |
Commande minimale: | 1 Set |
Packaging Detail: | wooden case |
Heure de livraison: | 25-30 days against the deposit or L/C |
Capacité de Fournir: | 40 Set per Month |
Payment Type: | L/C, T/T |
Groupe de produits : | Neutral Grounding Resistors |